Our Passtcert expert team use their experience for many people participating in Cisco certification 300-180 exam to develope the latest effective Cisco Certification 300-180 DCIT dumps pdf free, which includes CCNP Data Center 300-180 certification simulation test, the current exam and answers. Our Passtcert Cisco Certification 300-180 DCIT dumps pdf free have 95% similarity with the real exam. With Passtcert training tool your Cisco certification 300-180 exams can be easy passed.Why do most people choose Passtcert? Because Passtcert could bring great convenience and applicable.


I believe that people want to have good prospects of career whatever industry they work in. Of course, there is no exception in the competitive IT industry. IT Professionals working in the IT area also want to have good opportunities for promotion of job and salary. A lot of IT professional know that Cisco certification 300-180 exam can help you meet these aspirations. Passtcert Cisco Certification 300-180 DCIT dumps pdf free are a website which help you successfully pass Cisco 300-180.

Share some CCNP Data Center 300-180 exam questions and answers below.
A customer is configuring an upstream disjoint Layer 2 network in a Cisco UCS domain.
So far they have configured the following:
Fabric Interconnects are in switching mode.
There is symmetrical configuration for high availability.
There are no overlapping VLANs.
Each vNIC is communicating with one disjoint Layer 2 network.
After validating the above, the customer is still having issues with network connectivity.
What is the issue?
A. Overlapping VLANs are allowed in a disjoint Layer 2 network.
B. The vNIC configuration is incorrect and must communicate with two or more disjoint layer 2 networks.
C. The fabric interconnect must be in end-host mode for a disjoint Layer 2 network.
D. Asymmetrical configuration for high availability needs to be configured.
Answer: C

The Cisco UCS Manager displays FSM information for which four of these? (Choose four.)
A. which FSM task is being executed
B. the current state of an FSM task
C. the status of the previous FSM task
D. any error codes returned while processing
E. all completed FSM tasks
F. multiple FSM tasks that completed over multiple tries
G. multiple FSM tasks that failed
Answer: A, B, C, D

A customer is configuring SAN pin groups in a Cisco UCS domain. The customer notices that pinning is not working and traffic from the vHBA is not passing over the Fibre Channel uplink port.
Which of these must be done for pinning to work correctly?
A. Include the SAN pin group in a vHBA policy and then include the vHBA policy in the service profile that is assigned to that server.
B. Include the SAN policy in the Cisco UCS Manager to match with pin groups on the fabric interconnect.
C. The customer must have Cisco UCS Manager version 2.0 or above.
D. Fibre Channel switch mode needs to be configured first.
Answer: A

After migrating a server that is configured with dynamic vNICs, Cisco UCS Manager assigns new dynamic vNICs to the server.
If you had been monitoring traffic on an original dynamic vNIC, what must you do when the server comes back up?"
A. Reassign the dynamic vNIC back to the old configuration.
B. Nothing; Cisco UCS Manager will take over.
C. Reassign the service profile back to the master one.
D. Remove and reconfigure the dynamic vNIC.
E. Reassign the monitoring source.
Answer: E

Which commands can you enter to see if a component in the Cisco UCS domain generated a core file?
A. 6100-A# scope monitoring
6100-A /monitoring # scope sysdebug
6100-A /monitoring/sysdebug # show cores
Core Files:
Name Fabric ID
---------- ---------
B. 6100-A# scope sysdebug
6100-A /sysdebug # scope monitoring
6100-A /sysdebug/monitoring # show cores
Core Files:
Name Fabric ID
---------- ---------
C. 6100-A# scope system
6100-A /system # scope monitoring
6100-A /system/monitoring # show cores
Core Files:
Name Fabric ID
---------- ---------
D. 6100-A# scope cores
6100-A /cores # show cores
Core Files:
Name Fabric ID
---------- ---------
E. 6100-A# scope logging
6100-A /logging # scope monitoring
6100-A /logging/monitoring # show cores
Core Files:
Name Fabric ID
---------- ---------
Answer: A

Which piece of information does the FSM provide?
A. the current task and status
B. a collection of blade statistics
C. the last user to access the resource
D. a list of faults currently suppressed by the Cisco UCS Manager
Answer: A

When using the Cisco UCS Manager GUI to troubleshoot a suspected bad memory, which logs contain data that are related to the faulty DIMM?
A. the System Event log and Faults log that are located under the Admin tab
B. the Events log and Faults log that are located under the Admin tab
C. the System Event log that is located under the Server tab in the Navigation panel and the Faults log that is located under the Admin tab
D. the System Event log that is located under the Equipment tab and the Faults log that is located under the Admin tab
Answer: D

Which of these does not have an FSM associated with it?
A. vCenter connection
B. service profile
C. server hardware
D. service profile templates
Answer: D

In new Cisco UCS release 2.0 installations, what are the default VLAN IDs?
A. Ethernet VLAN default ID is 4048, FCOE default VLAN ID 4048
B. Ethernet VLAN default ID is 1, FCOE default VLAN ID is 3968
C. Ethernet VLAN default ID is 1, FCOE default VLAN ID is 2
D. Ethernet VLAN default ID is 2, FCOE default VLAN ID is 4047
E. Ethernet VLAN default ID is 1, FCOE default VLAN ID is 4048
Answer: E

Which three are valid tech support bundles to collect in the local management shell? (Choose three.)
A. UCSM
B. UCSM-MGMT
C. Port-Channel
D. Adapter
E. SAN
F. FEX
Answer: A, B, F

Which statement is true about system event logs?
A. By default, they require manual clearing.
B. They report operating system crashes and errors.
C. They are also referred to as system error logs.
D. They can only be accessed from Cisco UCS Manager.
Answer: A

How will the Cisco UCS Manager react when all of the FSM tasks fail?
A. retries for 60 seconds
B. raises faults and alarms
C. restarts from the previous known good task
D. sends an NOC SNMP trap email
Answer: B

Which protocols can be used to send to Cisco TAC (Technical Assistance Center) the show tech-support command output information about the Cisco UCS domain? (Choose two.)
A. TFTP
B. FTP
C. SCP
D. Telnet
E. SecureTelnet
Answer: B, C

A customer is configuring LAN pin groups in a Cisco UCS domain. The customer has two fabric interconnects and would like to associate the pin group with only one interconnect.
Which statement about this configuration is true?
A. In a system with two fabric interconnects, you can associate the pin group with only one fabric interconnect, and the other fabric interconnect will not be usable.
B. In a system with two fabric interconnects, you can only associate the pin group with both fabric interconnects; you cannot associate the pin group with only one fabric interconnect.
C. In a system with two fabric interconnects, you can associate the pin group with only one fabric interconnect or with both fabric interconnect. This is a supported configuration.
D. This configuration is not supported in a Cisco UCS domain.
Answer: C

With Passtcert, you no longer need to worry about the Cisco 300-180 exam. Passtcert exam questions have good quality and good service. As long as you choose Passtcert, Passtcert Cisco Certification 300-180 DCIT dumps pdf free will be able to help you pass the exam, and allow you to achieve a high level of efficiency in a short time.Passtcert is website that can help a lot of IT people realize their dreams.